| Temperature
Operating: -18 - +55 oC
Intermittent: -20 - +65 oC
Non Operating: -30 - +71 oC
Humidity
Operating/Storage MIL-STD-810C, Method 507.1 Proc. I, 95% RH
(non condensation)
Vibrations
Hard Mount: MIL-STD-810D, Method 514.3, Category 4, Table 514.3-II
& Fig. 514.3-25A
Shock Tray Mount: MIL-STD-810D, Method 514.3, Category 6.
Shock
Operating: MIL-STD-810D, Method 516.4, Proc. I, -15g 11ms. Saw Tooth
Explosive :MIL-5400, Par. 3.2.2.4.10
EMI/RFI : MIL-STD-461, Class 3
DRIP PROOF: MIL-STD-810E
Drip Proof : MIL-STD-810E, 95% RH (Non Condensing)
ALTITUDE:Operating: 15,000 ft.
Non Operating: 40,000 ft. |