Temperature
Operating: -30 - +55° C
Intermittent: -30 - +65°C
Non Operating: -45 - +71° C
Vibrations
Hard Mount: MIL-STD-810E, Method 514.4, Jet Aircraft
Humidity
Operating/Storage MIL-STD-810C Method 507 95% RH (non condensation)
Shock
Operating: MIL-STD-810E, Method 516.4, 15g 11ms Half Sine.
Explosive
MIL-E-5400T, Par. 3.2.24.10
EMI/RFI
MIL-STD-461C, Part 4
Drip Proof
MIL-STD-810E
Temperature-Altitude
MIL-E-5400T
Altitude
Operating
Operating:40,000 ft.
Non Operating:45,000 ft.
|